Green Glue Noiseproofing Clip

Product Specifications

Width 1.25 inch
Height 4.25 inch
Depth 1 inch
Weight .025 lbs
Max Spacing 48” on center
Recommended Load 36 lbs ~ 3 drywall layers
Max Safe Load 46 lbs ~ 4 drywall layers
Fail Load 300 lbs ~ 27 drywall layers


Sample Clip Layout

Green Glue Noiseproofing Clip layout

(1) Clips are spaced no further than 48 inches apart horizontally
(2) Hat channel must not be spaced more than 24 inches vertically
(3) Bottom clips must be less than 3 inches from the floor
(4) Top clips must be less than 6 inches from the ceiling

*Clips must be placed at the outermost studs on every piece of hat channel


Wall and Ceiling corner
Clip installed on stud

Step 1

Measure for placement of Green Glue Noiseproofing Clips using layout guidelines listed above. Mark locations and install clips using appropriate screws.

Recommended screws by stud type

Wood Use #8 x 2-1/2” coarse thread screws
Steel Use #8, 10 or 12 x 1-5/8” T ype S self-tapping screws
Concrete Use 3/16” dia x 2-1/4” T apcon or equal anchor Screw

Outermost clips must be placed at every interval to support the ends of the hat channel

Snap hat channel into clips

Step 2

Snap appropriate hat channel into clips

Recommended hat channel

Walls 25 gauge hemmed edges
Ceilings 22 gauge
Depth 7/8”
Width Top 1 ¼”
Width Bottom 2 ½”

Most walls will require you to overlap hat channel, instructions for doing so are as follows. Overlap 6 inches of hat channel between two clips. Secure the hat channel with two 7/16” framing screws. 18 gauge tie-wire can also be used.

Shim under drywall and screw to hat channel

Step 3

Place shims on the floor to allow spacing between the drywall and the flooring. This ensures decoupling from the floor to make it impossible for vibrations to travel from wall to floor and vice-verse.

Screw drywall in place through hat channel. Be sure drywall is fully installed before removing shims from underneath.



Step 4

Be sure to use an acoustical sealant to fill gaps around electrical boxes, windows, doors, and areas below or above sheets of drywall. Green Glue Noiseproofing Sealant is perfect for this application as it allows flexibility while stopping sound from transmitting through unsealed areas.